Isoflurane does not aggregate inside POPC bilayers at high pressure: Implications for pressure reversal of general anaesthesia - Institut Pasteur Access content directly
Journal Articles Chemical Physics Letters Year : 2015

Isoflurane does not aggregate inside POPC bilayers at high pressure: Implications for pressure reversal of general anaesthesia

Abstract

We placed isoflurane, a general anaesthetic, inside palmitoyloleoylphosphatidylcholine (POPC) bilay-ers at clinical concentration, and performed molecular dynamics simulations at atmospheric and raised pressures, using two different thermodynamic ensembles. We also performed a simulation of this system with isoflurane at ten times the clinical concentration. We found that isoflurane did not aggregate inside POPC membranes at 20 MPa, nor at 40 MPa. The implications of these findings for pressure reversal is discussed, in light of the high-pressure neurological syndrome.
Fichier principal
Vignette du fichier
180 CHAU.pdf (1.13 Mo) Télécharger le fichier
Origin : Publication funded by an institution
Loading...

Dates and versions

pasteur-01400870 , version 1 (22-11-2016)

Licence

Attribution - NonCommercial - NoDerivatives

Identifiers

Cite

J.R. Wieteska, P.R.L. Welche, K.-M. Tu, Mohammad Elgamacy, G. Csanyi, et al.. Isoflurane does not aggregate inside POPC bilayers at high pressure: Implications for pressure reversal of general anaesthesia. Chemical Physics Letters, 2015, 638, pp.116 - 121. ⟨10.1016/j.cplett.2015.07.065⟩. ⟨pasteur-01400870⟩